ASTM B117-07A PDF

The salt spray (or salt fog) test is a standardized and popular corrosion test method, used to ASTM B was the first internationally recognized salt spray standard, originally published in Other important relevant standards are. Designation: B – 07a Standard Practice for Operating Salt Spray (Fog) Apparatus1 This standard is issued under the?xed designation B. ASTM B Testing, also known as a Standard Practice for Operating Salt ASTM B Testing requires controls over many operational parameters such as: .

Author: Meztikinos Vudoll
Country: Sweden
Language: English (Spanish)
Genre: Medical
Published (Last): 22 March 2012
Pages: 488
PDF File Size: 11.42 Mb
ePub File Size: 4.47 Mb
ISBN: 687-9-33741-844-8
Downloads: 37619
Price: Free* [*Free Regsitration Required]
Uploader: Tygonris

Salt spray testing is popular because it is relatively inexpensive, quick, well standardized, and reasonably repeatable.

Practice B and Practice G 85 are considered to be most useful in estimating the relative behavior of closely related materials in marine atmospheres, since it simulates the basic conditions with some acceleration due to either wetness or temperature, or both. The zinc carbonates are not produced when a hot-dip galvanized specimen is exposed to a salt spray fog, therefore this testing method does not give an accurate measurement of corrosion protection.

SAL 3000-FL

Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. ASTM does not address this issue, but ISO does not recommend it and if it is to be done, advocates a thorough cleaning. The values given in parentheses are for information only. Views Read Edit View history. Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises the following 2 part repeating cycle.

Salt spray test

The company was founded in and from the very beginning it started working on innovative design concepts for test chambers. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, satm entirely their own responsibility. However, these testing standards neither provide information of testing periods for the coatings to be evaluated, nor the appearance of corrosion products in form of salts.

Related Articles  ANSI NEMA MG 1 2011 EBOOK DOWNLOAD

Otherwise cleaned air may be introduced into the bottom of a tower?

ASTM-B STANDARD PRACTICE FOR OPERATING SALT SPRAY (FOG) APPARATUS_百度文库

Asfm for corrosion chambers. A common method of introducing the air is through an air dispersion device X1. Technical features are subject to change without prior notice Power: NOTE 10—A solution having a speci? If these conditions are met, you can assume that your machine runs fine.

Suspension from glass hooks or waxed string may be used as long as the speci? Pending a complete understanding of air-pressure effects, and so forth, it is important that the nozzle selected shall produce the desired condition when operated at the air pressure selected. Although there may be a weak correlation between the duration in wstm spray test and the expected life of a coating in certain coatings such as hot dip galvanized steelthis test has gained worldwide popularity due to low cost and quick results.

Funnels and dishes with a diameter of 10 cm 3. When the pH of the salt solution is adjusted at room temperature, it is therefore necessary to adjust it below 6. Continuous operation implies that the chamber be closed and the spray operating continuously except for the short daily interruptions necessary to inspect, rearrange, or remove test satm, to check and replenish the solution in the reservoir, and to make necessary g117-07a as described in Section Is VLM only a distributor of corrosion test chambers?

Test specimens are placed in b117-077a enclosed chamber and exposed to a continuous indirect spray of salt water solution, prepared in accordance with the requirements of the test standard and acidified to pH 3.

The operating characteristics of a typical nozzle are given in Table X1. No, VLM has own development and production facilities for b17-07a testing equipment. This acceleration arises through the use of chemically altered salt spray solutions, often combined with other test climates and in most cases, the relatively rapid cycling of these test climates over time.

Related Articles  RS SALARIA DATA STRUCTURE EBOOK EBOOK DOWNLOAD

B117-07z, the materials to be tested are metallic although stone, ceramics, and polymers may also be tested and finished with a surface b117-007a which is intended to provide a degree of corrosion protection to the underlying metal.

This is followed by 1. The pH of the collected solution shall be 6. The sodium chloride concentration may also be determined using a suitable wstm meter for example, utilizing a sodium ion-selective glass electrode or colorimetrically as follows. Once a year the corrosivity of the salt spray test chamber has to be checked.

Test, Measure and Control. The major features of a walk-in type cabinet, which differs signi? Once a year the corrosivity of the salt spray test chamber has to be checked. Test specimens are placed in an enclosed ast, and exposed to 1 of 2 possible changing climate cycles. Please find more details at www. The fallout rate should be measured for 16 hours and it must range from 1. Please log in, in order to get access to prices, ordering and inquiry functions.

It is also useful for correlating the corrosive conditions among different cabinets. Place the panels in the proximity of the condensate collectors.

If the salt used is of lower purity, then test for halides. This may be done monthly or more frequently to ensure consistent operation over time. In the automotive industry requirements are specified under material specifications.

ISO standards by standard number. This standard has been approved for use by agencies of the Department of Defense. These standards describe the necessary information to carry out this test; testing parameters such as temperature, air pressure b117-70a the sprayed solution, preparation of the spraying solution, concentration, pHetc.